For dryer efficiency and safety, the shortest and straightest ducting route is always best. Every turn increases friction loss (unless you use non-restrictive elbows). Air velocity reduction from friction loss promotes lint build up and makes the dryer work harder to completely dry each load. Length of run also reduces efficiency. The longer the run, the more friction loss is created which is why building code restricts total run length. Often, going straight up through the roof is the shortest route.
While elbows and length-of-run are important factors for efficiency and safety, the exhaust termination is often the biggest restriction point. The DryerJack®, in fact, was born of extensive testing of the Dryerbox and Dryer-ell and how they improve airflow. In real-world tests, inefficient roof terminations would often all but negate the improved efficiency of eliminating restrictive elbows. While it sometimes made sense to vent through the roof, every roof vent that had previously been used was inefficient (often to a dangerous degree). In order to take advantage of the shortest route, a better termination was required
Problem Roof Vents | |||
WCI Airflow Reduction | .35 | .30 | .45 |
A Better Roof Termination
DryerJacks are the first roof vents designed to meet the more stringent venting requirements of dryer exhaust systems. Unlike the vents shown above-left, the DryerJack is dramatically more airflow efficient.
Considering that back pressure higher than .6 WCI is generally recognized as inefficient, you can see that venting through the roof with non-dryer specific vents is immediately problematic. The less back pressure is created by the roof vent, the more efficiently the system performs.
The new DryerJack is the most efficient. The position and curvature of the damper, combined with hood size, optimize airflow to such a degree that laboratory tests confirm only the most marginal reduction in airflow. Terminating the shorter duct run with a DryerJack helps venting through the roof deliver on the promise this shorter route offers.
At less than 5 1/2" above the roof plane, it is also low-profile for minimal visibility. For medium snowfall zones and / or higher profile roof tiles, select the larger model 486 which is as efficient but taller.